Gas Treatment Device
1. Filtering Device and Storage Canister: Typically, customers should already possess these components when undertaking treatment engineering. Ensure that these components are in optimal condition for efficient performance.
2.Desulfurization Device
Requirements for the Gas
1.The gas must be completely free from floating water or any dissociative substances. This ensures optimal performance and longevity of the system.
2. Gas thermal value must be ≥5000 kcal/l. If the thermal value falls below 5000 kcal/l, the power output of the gas generator sets will decrease. Ensure a consistent thermal value for reliable energy production.
3.The sulfur content must not exceed 250 mg/m³. If the gas contains more sulfur, a desulfurization process is required. It is imperative to maintain low sulfur levels to prevent damage and ensure efficient operation.
Note: Excessive sulfur content can cause severe damage to engine components. Regular monitoring and maintenance are essential for prolonged equipment life.
Model | Voltage (V) | Frequency(Hz) | Power(kW) | Speed (r/min) | Dimension(mm) | Weight (kg) |
AP4DG-30N5LC | 400 | 50 | 30 | 1500 | 1900×720×920 | 1000 |
AP4DG-50N5LC | 400 | 50 | 50 | 1500 | 1900×720×920 | 1020 |
AP4GG-60N5LC | 400 | 50 | 60 | 1500 | 1900×720×930 | 1100 |
AP6GG-80N5LC | 400 | 50 | 80 | 1500 | 2400×980×1450 | 1200 |
AP6GG-100N5LC | 400 | 50 | 100 | 1500 | 2400×980×1450 | 1250 |
AP6MKG-150N5LC | 400 | 50 | 150 | 1500 | 2900×1030×1780 | 2500 |
AP6MKG-180N5LC | 400 | 50 | 180 | 1500 | 2900×1030×1780 | 2500 |
AP6KG-200N5LC | 400 | 50 | 200 | 1500 | 3100×1300×1780 | 3200 |
AP6KG-250N5LC | 400 | 50 | 250 | 1500 | 3100×1300×1780 | 3200 |
AP6TG-300N5LC | 400 | 50 | 300 | 1500 | 3200×1400×1800 | 3800 |
AP6TDG-350N5LC | 400 | 50 | 350 | 1500 | 3270×1850×2150 | 5500 |
AP6TFG-500N5LC | 400 | 50 | 500 | 1500 | 3600×1500×2100 | 7400 |
AP6CG-500N5LC | 400 | 50 | 500 | 1500 | 4110×1633×2110 | 8890 |
AP6CG-600N5LC | 400 | 50 | 600 | 1500 | 4110×1630×2110 | 8890 |
AP12VTDG-700N5LC | 400 | 50 | 700 | 1500 | 3850×1950×2370 | 8490 |
AP12VTDG-700N5HC | 10500 | 50 | 700 | 1500 | 4415×2000×2370 | 9735 |
AP12VTDG-800N5LC | 400 | 50 | 800 | 1500 | 3850×1950×2370 | 8490 |
AP12VTDG-800N5HC | 10500 | 50 | 800 | 1500 | 4415×2000×2370 | 9735 |
AP12VCG-1000N5LC | 400 | 50 | 1000 | 1000 | 5190×2110×2660 | 16000 |
AP12VCG-1000N5HC | 10500 | 50 | 1000 | 1000 | 5480×2110×2690 | 17000 |
AP16VTDG-1100N5LC | 400 | 50 | 1100 | 1500 | 4620×1990×2280 | 11700 |
AP16VTDG-1100N5HC | 10500 | 50 | 1100 | 1500 | 5480×1990×2280 | 13750 |
AP16VCG-1500N5LC | 400 | 50 | 1500 | 1000 | 6030×2090×2745 | 22500 |
AP16VCG-1500N5HC | 10500 | 50 | 1500 | 1000 | 6030×2090×2645 | 22610 |
AP16VCG-2000N5LC | 400 | 50 | 2000 | 1500 | 8420×2055×2890 | 24800 |
AP16VCG-2000N5HC | 10500 | 50 | 2000 | 1500 | 8835×2055×2890 | 25500 |
Manufacturer of control panel | Smartgen brand HGM6120U |
Main function |
2.Acrylic screen, improved wearable and scratch resistance property; 3.Silica-gel panel and keys can well adapt to higher and lower temperature; 4.With RS485 communication port, can achieve "three remote" functions via MODBUS protocol; 5.Adapt to 3P4W, 3P3W, 1P2W and 2P3W (120V/240V), 50Hz/60Hz AC power system; 6.Can measure and display 3 phase voltage, 3 phase current, frequency, power parameter of mains/gens; 7.Mains have functions of over/under voltage and lack of phase; Gens have functions of over/under voltage, over/under frequency and over current; 8.Precision measure and display of parameters about engine, 9.Control protection: Automatic start/stop of genset, load transfer(ATS control) and perfect failure display and protection; 10.With ETS, idle speed control, pre-heat control, speed droop/raising control, all of them are relay output; 11.Parameter setting: Allow user to modify setting and store them in internal FLASH memory. The parameters cannot be lost even when power off. All of parameters can be set not only from the front panel, but also use programmable interface (or PS485 interface) to adjust them via PC.; 12.Multi sensors of temperature, pressure and fuel level can be used directly, parameters can be defined by user; 13.Multi conditions of crank disconnect (speed sensor, oil pressure, generator) can be selected; 14.Power supply range: (8~35)VDC, accommodating to different starting battery volts; 15.All parameters use digital modulation, instead of analog modulation using conventional potentiometer, having improved reliability and stability; 16.Add rubber gasket between shell and controller screen, the waterproof can reach IP55; 17.Controller is fixed by metal fixing clips; 18.Modular design, flame-retardant ABS shell, embedded mounting, compact structure and easy installation. |
ATS | Chinese brand together with generator |
Explore the Superior Benefits of Our Single Fuel Gas Gen Sets Compared to Industry StandardsDiscover how our products outshinethose in the same market:
1,Equipped with a state-of-the-art Hall Effect Sensor and a high-energy ignition system, guaranteeing reliable ignition and smooth start-up every time.
2,Incorporating top-tier American-origin electric governors technology and precision-engineered British-developed gas regulation systems technology for superior reliability and seamless operation.
3,Our gen sets are engineered to support parallel multi-set operations and seamless web integration, amplifying total capacity and simplifying maintenance routines, ensuring your production never halts. Such design ensures no interruption in your production process.
4,With engines crafted for optimal performance at lower rated power, we enhance engine reliability and extend its longevity.
5,The spare parts largely share compatibility with original diesel engines, making maintenance a breeze. The spark plug's cost is economically friendly at only2 USD per piece, reducing overall operational expenses.
6,These generators deliver exceptional economic performance with remarkably low operational costs.
7,Benefiting from the use of gas fuel, this leads to reduced carbon build-up, thus minimizing wear on cylinder liners and gas valve seats. This significantly extends the lifespan of our gen sets.
8,Utilizing an advanced control panel, these gen sets ensure unrivaled operational safety with a multitude of protection features.