Telecom Generator 15kVA -75kVA with 1000L 2000L Base Fuel Tank

Product Details
Customization: Available
After-sales Service: All Life
Warranty: 5 Year or 3000running Hrs Whichever Comes First
Gold Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

  • Telecom Generator 15kVA -75kVA with 1000L 2000L Base Fuel Tank
  • Telecom Generator 15kVA -75kVA with 1000L 2000L Base Fuel Tank
  • Telecom Generator 15kVA -75kVA with 1000L 2000L Base Fuel Tank
  • Telecom Generator 15kVA -75kVA with 1000L 2000L Base Fuel Tank
  • Telecom Generator 15kVA -75kVA with 1000L 2000L Base Fuel Tank
  • Telecom Generator 15kVA -75kVA with 1000L 2000L Base Fuel Tank
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Quality control & testing
  • Packaging & Shipping
  • Appgenset application
  • Exhibition
Overview

Basic Info.

Model NO.
AP15GFS-CU75GFS
Type
Self-Starting Diesel Generator
Installation Method
Fixed
Stroke
Four Stroke
Cooling Method
Water Cooling
Output Type
AC Three Phase
Speed
Speed
Conditions of Use
Land Use
Usage
Common Units, Standby Unit, Emergency Crew
Landuse Type of Unit
Low Noise
Excitation Mode
AC Rotating Exciter
Frequency
50/60Hz
Generator Type
Open Silent Mobile Container
Start Way
Machinery or Electric
Fuel Tank
8/10/12/24/72hrs Optional
Transport Package
Wrapping Film
Specification
15-75kva
Trademark
APPGENSET
Origin
China
HS Code
8502110000
Production Capacity
600units Per Month

Product Description

telecom generator 15kva 25kva 30kva 45kva 60kva 75kva with 1000L  2000L base fuel tank
 

Product Description

A telecom generator is a crucial piece of equipment in the telecommunications industry, mainly used to provide reliable power supply for telecom infrastructure. Here is a brief introduction:
 
  • Function and Importance: Telecom generators play a vital role in ensuring continuous and stable communication services. They act as backup power sources for telecom facilities like cell towers, data centers and network operation centers. During power outages or in areas with unreliable grid power, they kick in automatically to guarantee the normal operation of communication equipment, enabling uninterrupted voice and data transmission.
  • Types: There are various types of telecom generators. Diesel generators are widely used for their high power output and reliability. Gas generators are preferred in some environments for their relatively clean combustion. Besides, there are also solar generators and other renewable energy-powered generators, which are more environmentally friendly and suitable for areas with rich solar resources.
  • Features
    • High Reliability: Telecom generators are usually made of high-quality components and advanced manufacturing processes to ensure stable performance and low failure rates. Many also have redundant systems to enhance reliability.
    • Good Environmental Adaptability: They can work in a wide range of temperatures and are equipped with protection against dust, moisture and salt spray, enabling them to operate stably in harsh environments.
    • Low Noise: Especially for silent generator sets, they adopt soundproof enclosures and noise reduction technology to reduce noise pollution, which is very important in urban and residential areas.
    • Intelligent Management: Telecom generators are often equipped with intelligent control systems that allow for remote monitoring and control. Operators can check the operating status in real time and perform operations such as starting and stopping through mobile phones or computers.

 

Detailed Photos

Telecom Generator 15kVA -75kVA with 1000L 2000L Base Fuel Tank

Product Parameters

Genset Model Silent Type AP15GFS AP25GFS CU45GFS CU60GFS CU75GFS
Standby Power(kW/kVA) 12/15 20/25 36/45 48/60 60/75
  Pekins Series Cumins Series
 Diesel Engine  Model 403D-15G 404D-22G 4BT3,9-G2 4BTA3,9-G2 4BTA3,9-G11
Type water-cooled, in line, 4-stroke, direct injection
Standby Power(kW)   16 24 44 66 77
Intake Type Natural Natural Turbocharged Turbocharged Turbocharged
No.of Cylinder 3.L 4.L 4.L 4.L 4.L
Bore x Stroke(mm)   84x90 84x100 102x120 102x120 102x120
Displacement 1,496 2,216 3.9 3.9 3.9
Compression Ratio   22.5:1 23.3:1 16.5:1 16.5:1 16.5:1
Mechanical Governor Rate   <=5% <=5% <=5% <=5% <=5%
Electronic Governor Rate   <=1% <=1% <=1% <=1% <=1%
Noise Level (dBA)   <=75 <=75 <=75 <=75 <=75
Exhaust Temperature(°C)   445 445 475 475 475
Lub oil Capacity(L)   6 10.5 11 11 11
Rated Fuel Consumption(L/h)   2.5 4 8 11.5 14.3
Stmford technology Alternator Model 184E 184G 184H 224D 224E
Standby Power(kW/kVA)   12/15 20/25 36/45 48/60 60/75
Power Efficiency   85.7% 86.6% 88.6% 88.1% 89.6%
Voltage Regulation   <=±1 <=±1 <=±1 <=±1 <=±1
Excitation Type   Brushless Brushless Brushless Brushless Brushless
Insulation Class   H H H H H
Phases 1P 1P 3P 3P 3P
Voltage 230V 230V 230/127V 230/127V 230/127V
Controller Deepsea brand DSE6020 DSE6020 DSE6020 DSE6020 DSE6020
 
Overall Size(mm) Length 2050 2290 2550 2650 2650
Width 1120 1120 1120 1120 1120
Height 1350 1370 1570 1630 1630
Gross Weight(kg) 980 1080 1300 1360 1400
20GP Loading quantity(set) 5 5 4 4 4
40GP Loading quantity(set) 10 10 8 8 8
With fuel tank ,battery, battery charger, battery holder,oil and water seperator,lub oil valve,fuel meter,rubber shock absorber and 4 pieces spring  shock absorber per set,Delixi brand breaker,stainless screw, new design with high quality canopy .3 sets of diesel filter,oil filter ,air filter and belt per set.etc.

Quality control & testing

Telecom Generator 15kVA -75kVA with 1000L 2000L Base Fuel Tank

Packaging & Shipping

Telecom Generator 15kVA -75kVA with 1000L 2000L Base Fuel Tank

Appgenset application

Telecom Generator 15kVA -75kVA with 1000L 2000L Base Fuel Tank

Exhibition

 

Telecom Generator 15kVA -75kVA with 1000L 2000L Base Fuel Tank

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier