Customization: | Available |
---|---|
After-sales Service: | All Life |
Warranty: | One Year or 1200running Hrs Whichever Comes First |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Gas Treatment Device
1. Filtering Device and Storage Canister: For customers venturing into treatment engineering, these components are typically essential prerequisites.
2.Desulfurization Device
Requirements for the Gas
1.The gas must be impeccably free from floating water or any dissociative substances.
2. The gas thermal value should be ≥5000 kcal/l. A thermal value below this benchmark will lead to reduced power output from the gas generator sets.
3.Ensure the sulfur content remains below 250 mg/m³. Otherwise, an effective desulfurization process becomes imperative.
Note: High sulfur content poses a risk of significant damage to engine components and must be strictly monitored.
Model | Voltage (V) | Frequency(Hz) | Power(kW) | Speed (r/min) | Dimension(mm) | Weight (kg) |
AP4DG-30N5LC | 400 | 50 | 30 | 1500 | 1900×720×920 | 1000 |
AP4DG-50N5LC | 400 | 50 | 50 | 1500 | 1900×720×920 | 1020 |
AP4GG-60N5LC | 400 | 50 | 60 | 1500 | 1900×720×930 | 1100 |
AP6GG-80N5LC | 400 | 50 | 80 | 1500 | 2400×980×1450 | 1200 |
AP6GG-100N5LC | 400 | 50 | 100 | 1500 | 2400×980×1450 | 1250 |
AP6MKG-150N5LC | 400 | 50 | 150 | 1500 | 2900×1030×1780 | 2500 |
AP6MKG-180N5LC | 400 | 50 | 180 | 1500 | 2900×1030×1780 | 2500 |
AP6KG-200N5LC | 400 | 50 | 200 | 1500 | 3100×1300×1780 | 3200 |
AP6KG-250N5LC | 400 | 50 | 250 | 1500 | 3100×1300×1780 | 3200 |
AP6TG-300N5LC | 400 | 50 | 300 | 1500 | 3200×1400×1800 | 3800 |
AP6TDG-350N5LC | 400 | 50 | 350 | 1500 | 3270×1850×2150 | 5500 |
AP6TFG-500N5LC | 400 | 50 | 500 | 1500 | 3600×1500×2100 | 7400 |
AP6CG-500N5LC | 400 | 50 | 500 | 1500 | 4110×1633×2110 | 8890 |
AP6CG-600N5LC | 400 | 50 | 600 | 1500 | 4110×1630×2110 | 8890 |
AP12VTDG-700N5LC | 400 | 50 | 700 | 1500 | 3850×1950×2370 | 8490 |
AP12VTDG-700N5HC | 10500 | 50 | 700 | 1500 | 4415×2000×2370 | 9735 |
AP12VTDG-800N5LC | 400 | 50 | 800 | 1500 | 3850×1950×2370 | 8490 |
AP12VTDG-800N5HC | 10500 | 50 | 800 | 1500 | 4415×2000×2370 | 9735 |
AP12VCG-1000N5LC | 400 | 50 | 1000 | 1000 | 5190×2110×2660 | 16000 |
AP12VCG-1000N5HC | 10500 | 50 | 1000 | 1000 | 5480×2110×2690 | 17000 |
AP16VTDG-1100N5LC | 400 | 50 | 1100 | 1500 | 4620×1990×2280 | 11700 |
AP16VTDG-1100N5HC | 10500 | 50 | 1100 | 1500 | 5480×1990×2280 | 13750 |
AP16VCG-1500N5LC | 400 | 50 | 1500 | 1000 | 6030×2090×2745 | 22500 |
AP16VCG-1500N5HC | 10500 | 50 | 1500 | 1000 | 6030×2090×2645 | 22610 |
AP16VCG-2000N5LC | 400 | 50 | 2000 | 1500 | 8420×2055×2890 | 24800 |
AP16VCG-2000N5HC | 10500 | 50 | 2000 | 1500 | 8835×2055×2890 | 25500 |
Manufacturer of control panel | Smartgen brand HGM6120U |
Main function |
2.Acrylic screen, improved wearable and scratch resistance property; 3.Silica-gel panel and keys can well adapt to higher and lower temperature; 4.With RS485 communication port, can achieve "three remote" functions via MODBUS protocol; 5.Adapt to 3P4W, 3P3W, 1P2W and 2P3W (120V/240V), 50Hz/60Hz AC power system; 6.Can measure and display 3 phase voltage, 3 phase current, frequency, power parameter of mains/gens; 7.Mains have functions of over/under voltage and lack of phase; Gens have functions of over/under voltage, over/under frequency and over current; 8.Precision measure and display of parameters about engine, 9.Control protection: Automatic start/stop of genset, load transfer(ATS control) and perfect failure display and protection; 10.With ETS, idle speed control, pre-heat control, speed droop/raising control, all of them are relay output; 11.Parameter setting: Allow user to modify setting and store them in internal FLASH memory. The parameters cannot be lost even when power off. All of parameters can be set not only from the front panel, but also use programmable interface (or PS485 interface) to adjust them via PC.; 12.Multi sensors of temperature, pressure and fuel level can be used directly, parameters can be defined by user; 13.Multi conditions of crank disconnect (speed sensor, oil pressure, generator) can be selected; 14.Power supply range: (8~35)VDC, accommodating to different starting battery volts; 15.All parameters use digital modulation, instead of analog modulation using conventional potentiometer, having improved reliability and stability; 16.Add rubber gasket between shell and controller screen, the waterproof can reach IP55; 17.Controller is fixed by metal fixing clips; 18.Modular design, flame-retardant ABS shell, embedded mounting, compact structure and easy installation. |
ATS | Chinese brand together with generator |
Explore the Extraordinary Benefits of Our Single Fuel Gas Generator Sets Versus Industry NormsDiscover how our products stand out and excelfar beyond those available in the same competitive market:
1,Featuring state-of-the-art Hall Effect Sensors paired with a high-energy ignition system, our gen sets guarantee dependable ignition and smooth start-up every time.
2,Boasting American-engineered electric governor technology alongside British-crafted gas regulation systems technology to ensure superior reliability during all operations. 3,
Our gen sets are designed for parallel multi-set operations and seamless web integration, increasing total capacity and simplifying maintenance, ensuring your production never halts. Such advancements ensure continuous production flow without interruptions.
4,Our engines are engineered with lower rated power to boost engine reliability and extend longevity.
5, The spare parts are extensively compatible with original diesel engines making maintenance straightforward. The spark plug's price is just2 USD per piece, significantly reducing operating costs.
6,These high-performance generators offer exceptional economic efficiency with minimal operational expenses.
7,Benefiting from the use of gas fuel, carbon buildup is greatly reduced, minimizing wear on cylinder liners and gas valve seats. This greatly extends the lifespan of our generator sets.
8,Utilizing an advanced control panel, these generator sets ensure robust protection features for greater operational safety.