Customization: | Available |
---|---|
After-sales Service: | All Life |
Warranty: | One Year or 1200running Hrs Whichever Comes First |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Gas Treatment Device
1. Filtering Device and Storage Canister: Typically, customers have these components in place when undertaking treatment engineering.
2.Desulfurize Device
Requirement to the Gas
1.The gas must be free from dissociative water and any other dissociative substances.
2. Gas thermal value should be ≥5000kcal/l. If the thermal value is lower, the generator set's efficiency will decrease.
3.Sulfur content should be ≤250mg/m³. If the gas contains more sulfur, the sulfur content must be reduced.
Note: Excessive sulfur content can lead to serious damage to engine parts, so it's crucial to maintain optimal levels.
Model | Voltage (V) | Frequency(Hz) | Power(kW) | Speed (r/min) | Dimension(mm) | Weight (kg) |
AP4DG-30N5LC | 400 | 50 | 30 | 1500 | 1900×720×920 | 1000 |
AP4DG-50N5LC | 400 | 50 | 50 | 1500 | 1900×720×920 | 1020 |
AP4GG-60N5LC | 400 | 50 | 60 | 1500 | 1900×720×930 | 1100 |
AP6GG-80N5LC | 400 | 50 | 80 | 1500 | 2400×980×1450 | 1200 |
AP6GG-100N5LC | 400 | 50 | 100 | 1500 | 2400×980×1450 | 1250 |
AP6MKG-150N5LC | 400 | 50 | 150 | 1500 | 2900×1030×1780 | 2500 |
AP6MKG-180N5LC | 400 | 50 | 180 | 1500 | 2900×1030×1780 | 2500 |
AP6KG-200N5LC | 400 | 50 | 200 | 1500 | 3100×1300×1780 | 3200 |
AP6KG-250N5LC | 400 | 50 | 250 | 1500 | 3100×1300×1780 | 3200 |
AP6TG-300N5LC | 400 | 50 | 300 | 1500 | 3200×1400×1800 | 3800 |
AP6TDG-350N5LC | 400 | 50 | 350 | 1500 | 3270×1850×2150 | 5500 |
AP6TFG-500N5LC | 400 | 50 | 500 | 1500 | 3600×1500×2100 | 7400 |
AP6CG-500N5LC | 400 | 50 | 500 | 1500 | 4110×1633×2110 | 8890 |
AP6CG-600N5LC | 400 | 50 | 600 | 1500 | 4110×1630×2110 | 8890 |
AP12VTDG-700N5LC | 400 | 50 | 700 | 1500 | 3850×1950×2370 | 8490 |
AP12VTDG-700N5HC | 10500 | 50 | 700 | 1500 | 4415×2000×2370 | 9735 |
AP12VTDG-800N5LC | 400 | 50 | 800 | 1500 | 3850×1950×2370 | 8490 |
AP12VTDG-800N5HC | 10500 | 50 | 800 | 1500 | 4415×2000×2370 | 9735 |
AP12VCG-1000N5LC | 400 | 50 | 1000 | 1000 | 5190×2110×2660 | 16000 |
AP12VCG-1000N5HC | 10500 | 50 | 1000 | 1000 | 5480×2110×2690 | 17000 |
AP16VTDG-1100N5LC | 400 | 50 | 1100 | 1500 | 4620×1990×2280 | 11700 |
AP16VTDG-1100N5HC | 10500 | 50 | 1100 | 1500 | 5480×1990×2280 | 13750 |
AP16VCG-1500N5LC | 400 | 50 | 1500 | 1000 | 6030×2090×2745 | 22500 |
AP16VCG-1500N5HC | 10500 | 50 | 1500 | 1000 | 6030×2090×2645 | 22610 |
AP16VCG-2000N5LC | 400 | 50 | 2000 | 1500 | 8420×2055×2890 | 24800 |
AP16VCG-2000N5HC | 10500 | 50 | 2000 | 1500 | 8835×2055×2890 | 25500 |
Manufacturer of control panel | Smartgen brand HGM6120U |
Main function |
2.Acrylic screen, improved wearable and scratch resistance property; 3.Silica-gel panel and keys can well adapt to higher and lower temperature; 4.With RS485 communication port, can achieve "three remote" functions via MODBUS protocol; 5.Adapt to 3P4W, 3P3W, 1P2W and 2P3W (120V/240V), 50Hz/60Hz AC power system; 6.Can measure and display 3 phase voltage, 3 phase current, frequency, power parameter of mains/gens; 7.Mains have functions of over/under voltage and lack of phase; Gens have functions of over/under voltage, over/under frequency and over current; 8.Precision measure and display of parameters about engine, 9.Control protection: Automatic start/stop of genset, load transfer(ATS control) and perfect failure display and protection; 10.With ETS, idle speed control, pre-heat control, speed droop/raising control, all of them are relay output; 11.Parameter setting: Allow user to modify setting and store them in internal FLASH memory. The parameters cannot be lost even when power off. All of parameters can be set not only from the front panel, but also use programmable interface (or PS485 interface) to adjust them via PC.; 12.Multi sensors of temperature, pressure and fuel level can be used directly, parameters can be defined by user; 13.Multi conditions of crank disconnect (speed sensor, oil pressure, generator) can be selected; 14.Power supply range: (8~35)VDC, accommodating to different starting battery volts; 15.All parameters use digital modulation, instead of analog modulation using conventional potentiometer, having improved reliability and stability; 16.Add rubber gasket between shell and controller screen, the waterproof can reach IP55; 17.Controller is fixed by metal fixing clips; 18.Modular design, flame-retardant ABS shell, embedded mounting, compact structure and easy installation. |
ATS | Chinese brand together with generator |
Discover the remarkable benefits of our single fuel gas gen sets, proudly crafted by Weifang Smart Power Generating Equipment Co., Ltd., and see how they fare against the competition.'s products within the same area:
1,Harness the power of advanced Hall Effect Sensors and a high-energy ignition system, ensuring a reliable ignition process and effortless start-up.
2,Leverage the cutting-edge electric governor technology from America technology and the sophisticated gas regulating systems from Britain technology to ensure unwavering reliability in gen set operations.
3,Our gen sets are designed to run in parallel with multiple units, seamlessly integrating into networks to enhance overall capacity while simplifying maintenance and inspection processes. Such innovation guarantees no disruption to your production processes.
4,With a lower engine rated power, our engines promise enhanced reliability and performance.
5,The gen sets' spare parts are largely interchangeable with original diesel engine components, simplifying maintenance procedures. The spark plug's cost a mere2 USD per piece, offering a low-cost usage advantage.
6,The gen sets boast outstanding economic efficiency with minimal running costs.
7,Benefit from reduced carbon build-up thanks to our gas fuel technology, minimizing wear on cylinder liners and gas valve seats. This innovation significantly extends the lifespan of the gen sets.
8,Utilize our high-performance control panel for comprehensive protection, ensuring the safe operation of gen sets.