Customization: | Available |
---|---|
After-sales Service: | All Life |
Warranty: | One Year or 1200running Hrs Whichever Comes First |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Gas Treatment Device
1. Filtering Device and Storage Canister: Typically, this component is already in place for customers engaged in gas treatment engineering.
2.Desulfurization Device
Requirements for the Gas
1.The gas must be free of dissociative water and other dissociative substances.
2. Gas must have a thermal value of ≥5000kcal/l. If the gas has a lower thermal value (thermal value <5000kcal/l), the generator set's power output will decrease.
3.Sulfur content must be less than or equal to 250mg/m³. If the gas contains more sulfur, it is crucial to remove the excess sulfur content.
Note: Excessive sulfur content can cause severe damage to engine components.
Model | Voltage (V) | Frequency(Hz) | Power(kW) | Speed (r/min) | Dimension(mm) | Weight (kg) |
AP4DG-30N5LC | 400 | 50 | 30 | 1500 | 1900×720×920 | 1000 |
AP4DG-50N5LC | 400 | 50 | 50 | 1500 | 1900×720×920 | 1020 |
AP4GG-60N5LC | 400 | 50 | 60 | 1500 | 1900×720×930 | 1100 |
AP6GG-80N5LC | 400 | 50 | 80 | 1500 | 2400×980×1450 | 1200 |
AP6GG-100N5LC | 400 | 50 | 100 | 1500 | 2400×980×1450 | 1250 |
AP6MKG-150N5LC | 400 | 50 | 150 | 1500 | 2900×1030×1780 | 2500 |
AP6MKG-180N5LC | 400 | 50 | 180 | 1500 | 2900×1030×1780 | 2500 |
AP6KG-200N5LC | 400 | 50 | 200 | 1500 | 3100×1300×1780 | 3200 |
AP6KG-250N5LC | 400 | 50 | 250 | 1500 | 3100×1300×1780 | 3200 |
AP6TG-300N5LC | 400 | 50 | 300 | 1500 | 3200×1400×1800 | 3800 |
AP6TDG-350N5LC | 400 | 50 | 350 | 1500 | 3270×1850×2150 | 5500 |
AP6TFG-500N5LC | 400 | 50 | 500 | 1500 | 3600×1500×2100 | 7400 |
AP6CG-500N5LC | 400 | 50 | 500 | 1500 | 4110×1633×2110 | 8890 |
AP6CG-600N5LC | 400 | 50 | 600 | 1500 | 4110×1630×2110 | 8890 |
AP12VTDG-700N5LC | 400 | 50 | 700 | 1500 | 3850×1950×2370 | 8490 |
AP12VTDG-700N5HC | 10500 | 50 | 700 | 1500 | 4415×2000×2370 | 9735 |
AP12VTDG-800N5LC | 400 | 50 | 800 | 1500 | 3850×1950×2370 | 8490 |
AP12VTDG-800N5HC | 10500 | 50 | 800 | 1500 | 4415×2000×2370 | 9735 |
AP12VCG-1000N5LC | 400 | 50 | 1000 | 1000 | 5190×2110×2660 | 16000 |
AP12VCG-1000N5HC | 10500 | 50 | 1000 | 1000 | 5480×2110×2690 | 17000 |
AP16VTDG-1100N5LC | 400 | 50 | 1100 | 1500 | 4620×1990×2280 | 11700 |
AP16VTDG-1100N5HC | 10500 | 50 | 1100 | 1500 | 5480×1990×2280 | 13750 |
AP16VCG-1500N5LC | 400 | 50 | 1500 | 1000 | 6030×2090×2745 | 22500 |
AP16VCG-1500N5HC | 10500 | 50 | 1500 | 1000 | 6030×2090×2645 | 22610 |
AP16VCG-2000N5LC | 400 | 50 | 2000 | 1500 | 8420×2055×2890 | 24800 |
AP16VCG-2000N5HC | 10500 | 50 | 2000 | 1500 | 8835×2055×2890 | 25500 |
Manufacturer of control panel | Smartgen brand HGM6120U |
Main function |
2.Acrylic screen, improved wearable and scratch resistance property; 3.Silica-gel panel and keys can well adapt to higher and lower temperature; 4.With RS485 communication port, can achieve "three remote" functions via MODBUS protocol; 5.Adapt to 3P4W, 3P3W, 1P2W and 2P3W (120V/240V), 50Hz/60Hz AC power system; 6.Can measure and display 3 phase voltage, 3 phase current, frequency, power parameter of mains/gens; 7.Mains have functions of over/under voltage and lack of phase; Gens have functions of over/under voltage, over/under frequency and over current; 8.Precision measure and display of parameters about engine, 9.Control protection: Automatic start/stop of genset, load transfer(ATS control) and perfect failure display and protection; 10.With ETS, idle speed control, pre-heat control, speed droop/raising control, all of them are relay output; 11.Parameter setting: Allow user to modify setting and store them in internal FLASH memory. The parameters cannot be lost even when power off. All of parameters can be set not only from the front panel, but also use programmable interface (or PS485 interface) to adjust them via PC.; 12.Multi sensors of temperature, pressure and fuel level can be used directly, parameters can be defined by user; 13.Multi conditions of crank disconnect (speed sensor, oil pressure, generator) can be selected; 14.Power supply range: (8~35)VDC, accommodating to different starting battery volts; 15.All parameters use digital modulation, instead of analog modulation using conventional potentiometer, having improved reliability and stability; 16.Add rubber gasket between shell and controller screen, the waterproof can reach IP55; 17.Controller is fixed by metal fixing clips; 18.Modular design, flame-retardant ABS shell, embedded mounting, compact structure and easy installation. |
ATS | Chinese brand together with generator |
Discover the exceptional benefits our single fuel gas generator sets offer, crafted meticulously by Weifang Smart Power Generating Equipment Co., Ltd., compared to competitors' offerings.'s products within the same area:
1,We employ state-of-the-art Hall Effect Sensors and a high-energy ignition system to ensure reliable ignition, making startup exceptionally easy and efficient.
2,Incorporating advanced American technology electric governors and British technology gas regulation systems, our gen sets operate with outstanding reliability and precision.
3,Our gen sets are designed for seamless parallel operation and web integration, enhancing total capacity and simplifying maintenance without disrupting your production. So it will no influence the production of the customer.
4,With lower engine rated power, our engines are designed for superior reliability and longevity.
5,The spare parts for our gen sets are largely interchangeable with original diesel engine components, ensuring hassle-free maintenance. The spark plug's price is incredibly economical at only2 USD /piece, leading to impressively low operating costs.
6,The economic efficiency is outstanding, as operating costs remain minimal.
7,By utilizing gas fuel, carbon accumulation is significantly reduced, which minimizes wear on cylinder liners and gas valve seats, extending the lifespan of our gen sets. This can extend the life of the gen sets.
8,Our high-performance control panel offers comprehensive protection features, ensuring the safest operation of our gen sets.